Back to the tutorial main page

REFMAC5 Tutorial - Part 1

Simple Refinement

In this tutorial, we will use REFMAC5 to perform simple refinement of a ribonuclease structure.

A basic working knowledge of the CCP4i2 GUI is assumed.

Before We Start

Required files:

Please click these links to access the files and save them to your computer.

Contents


Simple Refinement Using REFMAC5 From Within CCP4i2

We will begin by performing simple refinement of the ribonuclease structure:

That's all that's required in order to execute a round of refinement with REFMAC5, using default parameters.

Click the "Run" button on the top-right of the interface to run the job.

After a few seconds, the Results page will open, and will update after every refinement cycle. Notice that the current weight being applied to the X-ray term is displayed below the graph.

After the job has finished, the page will display a variety of information pertaining to the refinement.

Adjusting The Geometry Weight

By default, REFMAC5 automatically adjusts the relative weight between geometry and X-ray terms, updating the weight after each refinement cycle. For many cases it works sufficiently well. However, sometimes (especially at high resolution) the default weighting may give a relaxed geometry. In such cases, you can play with the geometry weight.

To adjust the geometry weight:

What differences can you see between this refinement round and the previous refinement round that used automatic weighting?

Choosing an appropriate geometry weight

For low resolution data, you may want to use very small values - 0.01 or even smaller. At higher resolutions, this number may need to be as high as 10. You may need to run refinement multiple times using different values in order to get it right.

If after refinement the RMS bond distance is greater than 0.02 then you may want to reduce the weight, if the RMS bond distance is less than 0.01 then you may need to increase the weight.

A smaller weight means tighter geometry.

In order to know what weight to try, it is worth knowing the weight that REFMAC5 applies automatically. Then you can tighten or loosen the geometry weight by multiplying that value by e.g. 0.5 or 2, as appropriate. The weight that REFMAC5 applies can be found on the line directly below the graph on the Results page.

Inspecting the Electron Density

It is always important to manually inspect the electron density following refinement:

When you are finished, open the "File" menu and select "Save to CCP4i2". This will pass your editted model back to CCP4i2 for use in further jobs. Open the "File" menu and select "Exit" to close Coot and return to CCP4i2.

Back to the tutorial main page